Welcome to Gaps Water Treatment learn more

Fast delivery starting from £9.00 Learn more

Competitive pricing on Spectrum Filter range learn more

  • Standard delivery

    Delivery within 2-3 working days

  • Order by 3pm

    Orders processed same day

  • Easy returns

    Hassle free returns policy

  • Live Support

    Mon - Fri (9am to 4pm)

Herco UO-D 1500 FU CD 1500 lph Reverse Osmosis System with Duplex Softener 420 244

SKU: 5110010198
£24,308.00
Tax included Shipping calculated at checkout.


Description

Product Description

The ready-to-connect combi unit includes a pre-filter, a backflow preventer, a duplex water softener, a limitron hardness control device and a reverse osmosis unit. It is used for the desalination of water with a salinity of up to 1,000 mg/l and is equipped with a high-quality centrifugal pump with variable-speed drive (VSD = FU). Frequency-controlled operation reduces electricity cost by 30 - 50 %, extends the lifespan of the unit and keeps permeate production constant irrespective of operation pressure. The RO digital microprocessor controller enables fully automatic operation with logging of all relevant operating data and freely adjustable limit values. The unit can be connected to the central control system via an optional Profinet interface.

Benefits

• Compact unit
• Equipment with VSD (FU) saves 30 - 50 % electricity cost, maintains permeate production constant and enables a longer lifespan as well as • particularly quiet operation
• Continuous operation due to duplex softening
• Versatile RO digital controller with logging of operation data and many parametrization options

Applications

• Continuous water softening and desalination
• Suitable for all commercial and industrial applications
• Suitable for reduction of electricity cost

Controller : RO digital
Desalination rate min.: 97 %
Permeate recovery: 75 – 80 %
Permeate back pressure max.: 0.3 bar
pH value operation: 3.6 – 9.5
pH value cleaning: 2 – 12
Ambient temperature: 5 – 40 °C

Conditions of use: The unit may only be used for the desalination of feed water with drinking water quality or appropriately pre-treated well or surface water. The unit is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:

Free chlorine: not detectable
Iron (Fe): < 0.2 mg/l
Manganese (Mn): < 0.05 mg/l
Silica (SiO2): < 25 mg/l
Silt density index (SDI): < 3
Feed water temperature: 5 – 35 °C
Feed water pressure: 4 – 6 bar
Pressure fluctuation: ± 0.5 bar

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Wycombe

Herco UO-D 1500 FU CD 1500 lph Reverse Osmosis System with Duplex Softener 420 244

£24,308.00

Product Description

The ready-to-connect combi unit includes a pre-filter, a backflow preventer, a duplex water softener, a limitron hardness control device and a reverse osmosis unit. It is used for the desalination of water with a salinity of up to 1,000 mg/l and is equipped with a high-quality centrifugal pump with variable-speed drive (VSD = FU). Frequency-controlled operation reduces electricity cost by 30 - 50 %, extends the lifespan of the unit and keeps permeate production constant irrespective of operation pressure. The RO digital microprocessor controller enables fully automatic operation with logging of all relevant operating data and freely adjustable limit values. The unit can be connected to the central control system via an optional Profinet interface.

Benefits

• Compact unit
• Equipment with VSD (FU) saves 30 - 50 % electricity cost, maintains permeate production constant and enables a longer lifespan as well as • particularly quiet operation
• Continuous operation due to duplex softening
• Versatile RO digital controller with logging of operation data and many parametrization options

Applications

• Continuous water softening and desalination
• Suitable for all commercial and industrial applications
• Suitable for reduction of electricity cost

Controller : RO digital
Desalination rate min.: 97 %
Permeate recovery: 75 – 80 %
Permeate back pressure max.: 0.3 bar
pH value operation: 3.6 – 9.5
pH value cleaning: 2 – 12
Ambient temperature: 5 – 40 °C

Conditions of use: The unit may only be used for the desalination of feed water with drinking water quality or appropriately pre-treated well or surface water. The unit is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:

Free chlorine: not detectable
Iron (Fe): < 0.2 mg/l
Manganese (Mn): < 0.05 mg/l
Silica (SiO2): < 25 mg/l
Silt density index (SDI): < 3
Feed water temperature: 5 – 35 °C
Feed water pressure: 4 – 6 bar
Pressure fluctuation: ± 0.5 bar

View product