Welcome to Gaps Water Treatment learn more

Fast delivery starting from £9.00 Learn more

Competitive pricing on Spectrum Filter range learn more

  • Standard delivery

    Delivery within 2-3 working days

  • Order by 3pm

    Orders processed same day

  • Easy returns

    Hassle free returns policy

  • Live Support

    Mon - Fri (9am to 4pm)

Testomat 2000 - Testomat 2000 Hardness Monitor 230v 100096

SKU: 4801010078
£7,359.60
Tax included Shipping calculated at checkout.


Description

Product Description

Product information "Testomat 2000®"

The process photometer Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants. Monitoring and quality control of softening plants with and without blending (Testomat 2000® reagent TH 2005–2250)
Monitoring and quality control of decarbonization plants (Testomat 2000® reagent TC 2050–2100) Measuring acidic values in decarbonization and desalination plants (Testomat 2000® reagent TM 2005) Monitoring of steam boilers (Testomat 2000® reagent TP 2100).

Performance profile:
• Menu-driven operation and programming via plain text display
• Determinal measuring ranges of residual hardness, total hardness, carbonate hardness, minus m value, p value by indicator selection
• Selection of hardness units in ° dH, ° f, ppm CaCO3 or mmol / l
• High-precision titration using a piston dosing pump
• Analysis initiation:
- Automatic interval operation (Interval pause adjustable from 0–99 min)
- External control
- Dynamic (fatigue-dependent interval operation)
- Quantity dependent via contact water meter
• Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functions
• Monitoring of two measuring points (Switching by external solenoid valves)
• Internal error documentation
• Programmable service address
• Indicator quantities: 100 and 500 ml bottles
• Programmable maintenance interval for maintenance request

Technical specifications

Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–45 °C
Water temperature: 10–40 °C
Dimensions (W x H x D): 380 x 480 x 280 mm
Operating pressure: 0.3–8 bar
Weight: approx. 9,5 kg
Menu Language: German, English, French, Polish, Dutch, Italian, Spanish
Measuring range: Water hardness: 0.89 - 448 ppm | Carbonate hardness: 8.9 - 358 ppm | p-value: 0.1 - 15 mmol/l | minus m-value: 0.05 - 0.5 mmol/l

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Wycombe

Testomat 2000 - Testomat 2000 Hardness Monitor 230v 100096

£7,359.60

Product Description

Product information "Testomat 2000®"

The process photometer Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants. Monitoring and quality control of softening plants with and without blending (Testomat 2000® reagent TH 2005–2250)
Monitoring and quality control of decarbonization plants (Testomat 2000® reagent TC 2050–2100) Measuring acidic values in decarbonization and desalination plants (Testomat 2000® reagent TM 2005) Monitoring of steam boilers (Testomat 2000® reagent TP 2100).

Performance profile:
• Menu-driven operation and programming via plain text display
• Determinal measuring ranges of residual hardness, total hardness, carbonate hardness, minus m value, p value by indicator selection
• Selection of hardness units in ° dH, ° f, ppm CaCO3 or mmol / l
• High-precision titration using a piston dosing pump
• Analysis initiation:
- Automatic interval operation (Interval pause adjustable from 0–99 min)
- External control
- Dynamic (fatigue-dependent interval operation)
- Quantity dependent via contact water meter
• Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functions
• Monitoring of two measuring points (Switching by external solenoid valves)
• Internal error documentation
• Programmable service address
• Indicator quantities: 100 and 500 ml bottles
• Programmable maintenance interval for maintenance request

Technical specifications

Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–45 °C
Water temperature: 10–40 °C
Dimensions (W x H x D): 380 x 480 x 280 mm
Operating pressure: 0.3–8 bar
Weight: approx. 9,5 kg
Menu Language: German, English, French, Polish, Dutch, Italian, Spanish
Measuring range: Water hardness: 0.89 - 448 ppm | Carbonate hardness: 8.9 - 358 ppm | p-value: 0.1 - 15 mmol/l | minus m-value: 0.05 - 0.5 mmol/l

View product