Herco UO 120 CD 120 lph Reverse Osmosis System with Duplex Softener 420 201
Herco UO 120 CD 120 lph Reverse Osmosis System with Duplex Softener 420 201 is backordered and will ship as soon as it is back in stock.
Product Description
The ready-to-connect combi unit includes a pre-filter, a backflow preventer, a duplex water softener, a limitron hardness control device and a reverse osmosis unit. It is used for the desalination of water with a salinity of up to 1,000 mg/l and is equipped with a compact rotary vane pump. The RO 524 controller allows fully automatic operation without logging of operation data and with fixed, factory-set limit values.
Fitted with 1 x 4021 membrane.
Dimensions in mm: 1130 wide x 760 deep x 1520 height
Applications
Continuous water softening and desalination
Suitable for commercial and industrial applications that do not require operation data logging and parametrization
Controller : RO 524
Desalination rate min.: 97 %
Permeate recovery: 75 – 80 %
Permeate back pressure max.: 0.3 bar
pH value operation: 3.6 – 9.5
pH value cleaning: 2 – 12
Ambient temperature: 5 – 40 °C
Conditions of use: The unit may only be used for the desalination of feed water with drinking water quality or appropriately pre-treated well or surface water. The unit is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:
Free chlorine: not detectable
Iron (Fe): < 0.2 mg/l
Manganese (Mn): < 0.05 mg/l
Silica (SiO2): < 25 mg/l
Silt density index (SDI): < 3
Feed water temperature: 5 – 35 °C
Feed water pressure: 3 – 6 bar
Pressure fluctuation: ± 0.5 bar