Herco UO-D 600 FU CD, 600 lph Reverse Osmosis System with Duplex Softener 420 241

Herco UO-D 600 FU CD, 600 lph Reverse Osmosis System with Duplex Softener 420 241

Ref: 5110010186

Ready-to-connect system including pre-treatment for desalination of drinking water according to drinking water regulations (free chlorine not detectable).

Due to integrated water pre-treatment components such as pre-filter, backflow preventer, duplex water softener and limitron hardness monitoring unit a piping on site is not necessary. Only 4 connections required (drinking water, permeate, waste water and mains connection). Continuous production of permeate possible.

Up to 30% energy savings due to high pressure pump with frequency converter (FU) with control of permeate flow rate at constant value (PKR). Particularly quiet operation.

membranes: 4040 x 2

FEATURES

• Skid mounted, complete unite
• Duplex softener Clack CI Twin 2 x 50L (600-900l/h) or 2 x 100L (1200-2000l/h) mono resins
• RO Digital controller
• Recovery from 75% to 80%
• Salt rejection percentage: min. 97%
• Working pressure: 14 bar
• Voltage: 3 phase 400V / 50 Hz
• Digital flow meters

ADVANTAGES

• Energy savings of up to 30%
• Automatic regulation PKR for constant permeate rates even at fluctuating operating conditions included
• Particularly quiet operation

ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

LIMITRON
oops
Safety device to protect the membranes in case of softener malfunctioning. In case hardness is detected, the RO will automatically shut off.
This is always an advised option but most relevant when:
• Pre-treatment is a simplex softener
• Inlet hardness is variable
• There is limited maintenance and/or no guaranteed operator for salt refilling

PKR - CONSTANT PERMEATE FLOW CONTROL
oops
Regulation of the permeate capacity to a defined value, using a high-pressure pump with frequency converter.

The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a max. colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after 3 years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.

Price: 15,430.00 (18,516.00 Including VAT at 20%)

Ready-to-connect system including pre-treatment for desalination of drinking water according to drinking water regulations (free chlorine not detectable).

Due to integrated water pre-treatment components such as pre-filter, backflow preventer, duplex water softener and limitron hardness monitoring unit a piping on site is not necessary. Only 4 connections required (drinking water, permeate, waste water and mains connection). Continuous production of permeate possible.

Up to 30% energy savings due to high pressure pump with frequency converter (FU) with control of permeate flow rate at constant value (PKR). Particularly quiet operation.

membranes: 4040 x 2

FEATURES

• Skid mounted, complete unite
• Duplex softener Clack CI Twin 2 x 50L (600-900l/h) or 2 x 100L (1200-2000l/h) mono resins
• RO Digital controller
• Recovery from 75% to 80%
• Salt rejection percentage: min. 97%
• Working pressure: 14 bar
• Voltage: 3 phase 400V / 50 Hz
• Digital flow meters

ADVANTAGES

• Energy savings of up to 30%
• Automatic regulation PKR for constant permeate rates even at fluctuating operating conditions included
• Particularly quiet operation

ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

LIMITRON
oops
Safety device to protect the membranes in case of softener malfunctioning. In case hardness is detected, the RO will automatically shut off.
This is always an advised option but most relevant when:
• Pre-treatment is a simplex softener
• Inlet hardness is variable
• There is limited maintenance and/or no guaranteed operator for salt refilling

PKR - CONSTANT PERMEATE FLOW CONTROL
oops
Regulation of the permeate capacity to a defined value, using a high-pressure pump with frequency converter.

The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a max. colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after 3 years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.