My Cart

Items:  items
Value: 

Herco UO-D 10000 AS/FU, 10000 lph Reverse Osmosis System with Dosing Station Ready, 387 077,

Herco UO-D 10000 AS/FU, 10000 lph Reverse Osmosis System with Dosing Station Ready, 387 077,

Ref: 5110050036

For desalination of hardness stabilised drinking water according to drinking water regulations.

Up to 30% energy savings due to high pressure pump with frequency converter (FU)

Control for antiscalant metering pump AS-K, connection set for manual cleaning unit ARA, concentrate flushing device KSE, preparation for an injection point and control to regulate permeate flow rate at constant value PKR (only series ND/FU).

Membranes:8040 x 9

FEATURES

• Complete unit skid mounted
• RO Digital controller
• Recovery: 75%
• Salt rejection percentage: min. 97%
• Design pressure: 11,5 to 13 bar (depending on type)
• Voltage: 3 phase 400V / 50 Hz
• Digital flow meters
• Profinet interface (option)
• Incl. concentrate rinsing
• Incl. connector kit for manual cleaning set
• Prepared for a dosing station with antiscalant
• Prepared for a dosing station with antiscalant

ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

PKR - CONSTANT PERMEATE FLOW CONTROL
oops
Regulation of the permeate capacity to a defined value, using a high-pressure pump with frequency converter.
*The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pretreatment.

Price: 39,000.00 (46,800.00 Including VAT at 20%)

For desalination of hardness stabilised drinking water according to drinking water regulations.

Up to 30% energy savings due to high pressure pump with frequency converter (FU)

Control for antiscalant metering pump AS-K, connection set for manual cleaning unit ARA, concentrate flushing device KSE, preparation for an injection point and control to regulate permeate flow rate at constant value PKR (only series ND/FU).

Membranes:8040 x 9

FEATURES

• Complete unit skid mounted
• RO Digital controller
• Recovery: 75%
• Salt rejection percentage: min. 97%
• Design pressure: 11,5 to 13 bar (depending on type)
• Voltage: 3 phase 400V / 50 Hz
• Digital flow meters
• Profinet interface (option)
• Incl. concentrate rinsing
• Incl. connector kit for manual cleaning set
• Prepared for a dosing station with antiscalant
• Prepared for a dosing station with antiscalant

ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

PKR - CONSTANT PERMEATE FLOW CONTROL
oops
Regulation of the permeate capacity to a defined value, using a high-pressure pump with frequency converter.
*The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pretreatment.