Herco UO 3500 KR FU, 3500 lph High Efficiency Reverse Osmosis System 381-837

Herco UO 3500 KR FU, 3500 lph High Efficiency Reverse Osmosis System  381-837

Ref: 5110010017

For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).

Very high permeate recovery up to 90 % due to additional concentrate stage and high salt rejection up to 98.5 %. Short ROI/ payback period (mostly < 1 year) through savings in water and waste water. Concentrate flushing device KSE and connection kit ARA already integrated.
oops
membranes: 4040 x 14

Up to 30% energy savings due to high pressure pump with frequency converter.

FEATURES

• Skid mounted, complete unite
• RO 5000 controller
• Recovery from 85% to 90%
• Salt rejection percentage: min. 98,5%
• Working pressure: 15 to 18,5 bar (depending on type)
• Inlet pressure: 2 to 4 bar
• Voltage: 3 x 380V
• Analogue flow meters
• Incl. concentrate rinsing
• Incl. connector kit for manual cleaning set

ADVANTAGES

• Water saving system through additional concentrate stage: permeate yield up to 90%
• High salt rejection rate: 98,5%
• Very low energy consumption KR/FU: -30%
• ROI/ payback period: < 1 year through cost savings in water, waste water and energy


ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

*The unit is designed for a maximum TDS of 1,000 mg/l, a max. SiO2-concentration of 10 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and no permeate back pressure. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.

Price: 24,900.00 (29,880.00 Including VAT at 20%)

For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).

Very high permeate recovery up to 90 % due to additional concentrate stage and high salt rejection up to 98.5 %. Short ROI/ payback period (mostly < 1 year) through savings in water and waste water. Concentrate flushing device KSE and connection kit ARA already integrated.
oops
membranes: 4040 x 14

Up to 30% energy savings due to high pressure pump with frequency converter.

FEATURES

• Skid mounted, complete unite
• RO 5000 controller
• Recovery from 85% to 90%
• Salt rejection percentage: min. 98,5%
• Working pressure: 15 to 18,5 bar (depending on type)
• Inlet pressure: 2 to 4 bar
• Voltage: 3 x 380V
• Analogue flow meters
• Incl. concentrate rinsing
• Incl. connector kit for manual cleaning set

ADVANTAGES

• Water saving system through additional concentrate stage: permeate yield up to 90%
• High salt rejection rate: 98,5%
• Very low energy consumption KR/FU: -30%
• ROI/ payback period: < 1 year through cost savings in water, waste water and energy


ARA - CONNECTION KIT FOR MANUAL CLEANING UNIT
oops
Ball valves for the connection of a manual cleaning unit e.g. for acid or alkali cleaning of the RO membrane.
Advantages:
• Easier to make the cleaning as the piping’s do not need to be disconnected first.
• Economy of time for making the cleaning
• Avoiding mistakes

*The unit is designed for a maximum TDS of 1,000 mg/l, a max. SiO2-concentration of 10 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and no permeate back pressure. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.